MV-DP3060-01D
HIKROBOT
Gigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s)
1.3 kHz (within max. measurement range), max. 19 kHz (in ROI mode)
Availability: | |
---|---|
Quantity: | |
Key Features:
Dual-mode image sensor design effectively eliminates field-of-view (FOV) blind spots and suppresses stray light interference, ensuring more complete and accurate data acquisition.
Integrated high-precision 3D algorithms deliver exceptional repeatability with accuracy reaching the submicron level, ideal for ultra-fine measurement applications.
Equipped with a high-frame-rate image sensor, supporting scan rates up to 19 KHz, enabling fast and efficient 3D data capture in dynamic environments.
Supports multiple exposure modes, allowing flexible adaptation to complex lighting conditions and ensuring a wider dynamic range for enhanced image quality.
Utilizes advanced image fusion algorithms to generate more complete and detailed point cloud data, improving 3D reconstruction accuracy.
Offers multiple selectable filtering modes to optimize output, delivering stable and reliable point cloud data even in challenging operational environments.
Overall dimensions
Key Features:
Dual-mode image sensor design effectively eliminates field-of-view (FOV) blind spots and suppresses stray light interference, ensuring more complete and accurate data acquisition.
Integrated high-precision 3D algorithms deliver exceptional repeatability with accuracy reaching the submicron level, ideal for ultra-fine measurement applications.
Equipped with a high-frame-rate image sensor, supporting scan rates up to 19 KHz, enabling fast and efficient 3D data capture in dynamic environments.
Supports multiple exposure modes, allowing flexible adaptation to complex lighting conditions and ensuring a wider dynamic range for enhanced image quality.
Utilizes advanced image fusion algorithms to generate more complete and detailed point cloud data, improving 3D reconstruction accuracy.
Offers multiple selectable filtering modes to optimize output, delivering stable and reliable point cloud data even in challenging operational environments.
Overall dimensions
Model | Product Model | MV-DP3060-01D |
Type | MV-DP3060-01D | |
Performance | Data points/profile | 3200 |
Reference distance | 60 mm | |
Measurement range (Z-axis) | 20.5 mm | |
Measurement range (X-axis) | 27.5 mm @ near field of view 30.5 mm @ reference distance 33.5 mm @ far field of view | |
Resolution (Z-axis) | 1.45 μm to 2.17 μm | |
Repeatability (Z-axis)* | 0.44 μm @ data that sensor tests gauge block on optical platform | |
Linearity Z-axis (±% of MR) | 0.008 | |
Profile data interval | 8.9 μm to 11.1 μm | |
Scan frame rate | 1.3 kHz (within max. measurement range), max. 19 kHz (in ROI mode) | |
Data output | Profile data, depth image, brightness image, width image | |
Trigger mode | Software trigger, hardware trigger (differential encoder) | |
Laser safety class | Class 3R | |
Wavelength | 405 nm | |
Electrical feature | Data interface | Gigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s) |
Digital I/O | 12-pin M12 interface provides power and I/O, including differential input × 3 (Line 0/3/6), differential output × 1 (Line 1), and RS-232 × 1 | |
Power supply | 24 VDC | |
Power consumption | Typ. 21 W @ 24 VDC | |
Mechanical | Dimension | 258 mm × 97.5 mm × 66 mm (10.2" × 3.8" × 2.6") |
Weight | Approx. 1510 g (3.3 lb.) | |
Ingress protection | IP67 | |
Temperature | Working temperature: 0 °C to 45 °C (32 °F to 113 °F) Storage temperature: –30 °C to 80 °C (–22 °F to 176 °F) | |
Humidity | 20% RH to 85% RH (no condensation) | |
General | Client software | 3DMVS, VM3D, or other 3D software |
Operating system | 32/64-bit Windows 7/10, 64-bit Windows 11 (8 GB memory and above, and i5 CPU recommended) |
Model | Product Model | MV-DP3060-01D |
Type | MV-DP3060-01D | |
Performance | Data points/profile | 3200 |
Reference distance | 60 mm | |
Measurement range (Z-axis) | 20.5 mm | |
Measurement range (X-axis) | 27.5 mm @ near field of view 30.5 mm @ reference distance 33.5 mm @ far field of view | |
Resolution (Z-axis) | 1.45 μm to 2.17 μm | |
Repeatability (Z-axis)* | 0.44 μm @ data that sensor tests gauge block on optical platform | |
Linearity Z-axis (±% of MR) | 0.008 | |
Profile data interval | 8.9 μm to 11.1 μm | |
Scan frame rate | 1.3 kHz (within max. measurement range), max. 19 kHz (in ROI mode) | |
Data output | Profile data, depth image, brightness image, width image | |
Trigger mode | Software trigger, hardware trigger (differential encoder) | |
Laser safety class | Class 3R | |
Wavelength | 405 nm | |
Electrical feature | Data interface | Gigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s) |
Digital I/O | 12-pin M12 interface provides power and I/O, including differential input × 3 (Line 0/3/6), differential output × 1 (Line 1), and RS-232 × 1 | |
Power supply | 24 VDC | |
Power consumption | Typ. 21 W @ 24 VDC | |
Mechanical | Dimension | 258 mm × 97.5 mm × 66 mm (10.2" × 3.8" × 2.6") |
Weight | Approx. 1510 g (3.3 lb.) | |
Ingress protection | IP67 | |
Temperature | Working temperature: 0 °C to 45 °C (32 °F to 113 °F) Storage temperature: –30 °C to 80 °C (–22 °F to 176 °F) | |
Humidity | 20% RH to 85% RH (no condensation) | |
General | Client software | 3DMVS, VM3D, or other 3D software |
Operating system | 32/64-bit Windows 7/10, 64-bit Windows 11 (8 GB memory and above, and i5 CPU recommended) |